WU Ying-xiong;DONG Xin-jun;LIAO Wen-bin;LIN You-qin;TANG Zhen-yun;ZHENG Guo-chen;SHANG Hao-jiang;College of Civil Engineering, Fuzhou University;Fujian Provincial Institute of Architectural Design and Research Co., Ltd.;The Key Laboratory of Urban Security and Disaster Engineering of Ministry of Education, Beijing University of Technology;College of Engineering, Fujian Jiangxia University;Fujian Academy of Building Research Co., Ltd.;

Abstract: There is a lack of detection means for the isolation performance of the buildings built by passive control technology, so it is of great significance to test the dynamic characteristics of the isolated structures on the spot. A 4-story base isolation kindergarten was tested in the field, and the test device, method and results were displayed. The results were compared with the seismic structure model under the same conditions, and the dynamic response law and damping effect of the actual isolati... More